4000SS Reduced Pressure Backflow Preventer, 3 in, Flange, 304/304L Stainless Steel
PartAME4000SSNRS3
MFGF0690488
Description
Ames Fire & Waterworks®, F0690488, Backflow Preventer with Flood Sensor, Straight, Series: 4000SS-FS, 3 in Nominal, Flanged End Style, 175 psi Pressure, 33 to 110 deg F, Non-Rising Stem Gate Valve Ball Valve/Gate Valve, Reduced Pressure Zone Backflow, Media: Water, Stainless Steel Body, Domestic
Price/Availability Accessible On Login
- Short end-to-end dimensions makes retrofit easy
- Cam-check assembly provides maximum flow at low pressure drop
- Top mounted test cocks
- Compact construction for smaller enclosures
- Stainless steel relief valve features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs
- Flood sensor with SentryPlus Alert technology to detect water discharges from the relief valve
- Flood alerts feature available with add-on sensor connection kit
- Stainless steel body is half the weight of competitive designs reducing installation and shipping costs
- Stainless steel construction provides long term corrosion resistance and maximum strength
This 3 inch lead free reduced pressure zone backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure. Its compact modular design facilitates easy maintenance with a single access cover for in-line repairs. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards and from other contaminants found at the service line entrance. This assembly consists of a short lay length lightweight stainless steel body, resilient seated shutoff valves with non-rising stem, test cocks, corrosive resistant stainless steel bottom mounted relief valve, and a patented cam-check assembly. This backflow assembly contains a flood sensor with SentryPlus Alert(R) technology to detect excessive water discharges from the relief valve. When activated through an add-on sensor connection kit, the flood sensor can send an alert to notify personnel about potential flooding. Add-on sensor connection kits are available for BMS and cellular communications.
| Nominal Size | 3 in |
| End Style | Flange |
| Body Material | 304/304L Stainless Steel |
| Series | 4000SS |
| Backflow Type | Reduced Pressure Zone |
| Ball Valve/Gate Valve Type | Resilient Seated Gate Valve |
| Dimensions | 38 in L |
| Domestic/Import | Domestic |
| Finish | Stainless Steel |
| Media | Water |
| Pressure Rating | 175 psi |
| Temperature Rating | 33 to 110 deg F |
| Type | Straight |
| Brand | Ames Fire & Waterworks® |
| Country of Origin | US |
| Manufacturer | Watts Water Technologies |
| UPC | 737733038184 |
| Manufacturer Part Number | F0690488 |
1 Year
ASSE 1013|cCSAus B64.5|cULus Classified|FM Approved|AWWA C511-92
Ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards and from other contaminants found at the service line entrance
Price/Availability Accessible On Login

Ames Fire & Waterworks®4000SS Reduced Pressure Backflow Preventer, 3 in, Flange, 304/304L Stainless Steel