4ALF-200 Reduced Pressure Backflow Preventer, 2-1/2 in, Flange, 304/304L Stainless Steel
PartAPO4ALF20902
MFG4ALF-209-02
Description
Apollo™, 4ALF20902, Backflow Preventer, Series: 4ALF-200 LBF, 2-1/2 in Nominal, NRS Flanged End Style, 175 psi Pressure, 33 to 140 deg F, Reduced Pressure Backflow, 304 Stainless Steel Body, 28 in L x 11-1/2 in W Dimensions, Domestic
Price/Availability Accessible On Login
- Easy maintenance - No special tools required
- Low pressure loss as documented by an independent laboratory
- Center-stem guided TriForce™ check valves
- Approved for horizontal flow
- Lead free: The wetted surfaces of this product shall contain no more than 0.25% lead by weighted average, complies with Federal Public Law 111-380, ANSI 3rd party approved and listed
The Apollo® MODEL RPLF 4A Reduced Pressure Principle Backflow Preventers consist of two independently acting, TriForce™ center stem guided check valves with a differential pressure relief valve located between the check valves. The unit is designed to give maximum protection against backflow of health or non-health hazard fluids by either back-pressure or back siphonage. The durable domestic stainless steel units (2-1/2 to 8 in) and the FDA epoxy coated ductile iron units (10 and 12 in) are easily maintained in the line without any special tools. The TriForce™ check valves operate with a spring assist in the flowing condition to provide excellent flow rates which are documented by an independent laboratory.
Nominal Size | 2-1/2 in |
End Style | Flange |
Body Material | 304/304L Stainless Steel |
Series | 4ALF-200 |
Backflow Type | Reduced Pressure |
Dimensions | 28 in L x 11-1/2 in W |
Domestic/Import | Domestic |
Pressure Rating | 175 psi |
Temperature Rating | 33 to 140 deg F |
Brand | Apollo™ |
UNSPSC | 40141600 |
Alternate Part Number 1 | RPLF |
Country of Origin | US |
Manufacturer | Apollo Conbraco |
UPC | 670750669330 |
Manufacturer Part Number | 4ALF-209-02 |
5 Years
ARRA Compliant|ASSE 1013|Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California|AWWA C511|CSA B64.4|FM Approved|TL Certified|IAPMO Certified|UL/cUL Listed|US Patents 6443184/7025085/7533699/8240333|US FCCCHR|PROP65: Cancer and Reproductive Harm
Horizontal Flow
Price/Availability Accessible On Login
- Recommended Accessories
- Competitive Brands
- Recently Viewed
No applicable products
No applicable products
No applicable products

Apollo™4ALF-200 Reduced Pressure Backflow Preventer, 2-1/2 in, Flange, 304/304L Stainless Steel
- Customers Also Purchased
No applicable products